ISO9000:2008 certified precision module .The XRD Series is ideal for OEM applications requiring a competitively priced, precision X-ray tube high voltage module. • MODELS FROM 1KV TO 70KV,300W-600W • STANDARD DIGITAL INTERFACES:USB, ETHERNET AND RS-232 • UNIVERSAL INPUT,POWER FACTOR CORRECTED • OVERVOLTAGE & SHORT CIRCUIT PROTECTION • VOLTAGE & CURRENT PROGRAMMING • LOCAL AND REMOTE EMISSION CONTROL • SAFETY INTERLOCK • OEM CUSTOMIZATION AVAILABLE wisman's new XRD Series of X-Ray generator modules are designed for OEM applications up to 70kV at 1200 watts.Its universal input, small package size and choice of three standard digital interfaces simplifies integrating the XRD into your X-Ray analy sisystem. Models are available to operate either floating filament (negative HV polarity)or ground referenced filament (positive HV polarity), X-Ray tube designs. DSP based sioncontrol circuitry provides excellent regulation of emission current, along with standing stability performance. TYPICAL APPLICATIONS Plastics Sorting, Crystal Inspection, Plating Measurement Diamond Inspection, Mineral Analysis, X-Ray Fluorescence , X-Ray Diffraction SPECIFICATIONS Input Voltage: Power factor corrected input 90-264Vac, 47-63 Hertz, for 300 watt units 180-264Vac, 47-63 Hertz for 600 and 1200 watt units Output Voltage: 6 models—20kV, 30kV, 40kV, 50kV, 60kV and 70kV Output Polarity: Negative-for floating filament X-ray tubes Positive-for ground referenced filament X-ray tubes Power 3 power ranges available—300 watts, 600 watts and 1200 watts . Other power levels available on special order. Output Voltage Regulation: ≤0.01% of rated output voltage over specified input voltage range ≤0.01% of rated output voltage for a full load change Emission Current Regulation: ≤0.01% of rated output current over specified input voltage range ≤0.01% of rated output current for a change from 30% to 100% of rated output voltage Ripple: ≤1%rms at >20 kHz, 0.1%rms below 20 kHz Stability: ≤25ppm/hr after a 2 hour warm up Filament Configuration: Closed loop emission control regulates filament setting to provide desired Xray tube emission current. Filament is disabled when kV is <30% of full scale output. Two types are available: Floating Filament (ac outputreferenced to negative output voltage) and Ground Referenced Filament (dc output referenced to ground). Filament Output: 0-5 amps at a compliance of 10 volts, maximum. Other filament levels available on special order. Temperature Coefficient: ≤50ppm per degree C Environmental: Temperature : Range:Operating: 0˚C to 40˚C; Storage: -40˚C to 85˚C Humidity:20% to 85% RH, non-condensing. Dimensions: 300/600W:12D×6W×4.75H(304mm×152mm×120mm) 1200W: 12D×12W×4.75H(304mm×304mm×120mm) Weight: 300/600W:14 pounds(6.35kg);1200W:26pounds(11.8kg) Voltage Control: Local: Internal multi-turn potentiometer to set voltage from 0 to full output voltage. Remote: 0 to +10Vdc proportional from 0 to full output voltage. Accuracy: ±1%. ZIN: 10Mohm. Emission Control: Local: Internal potentiometer to set beam current between 0 and full output. Remote: 0 to +10Vdc proportional from 0 to full output current. Accuracy : ±1%. ZIN: 10Mohm. Voltage and Current Monitors: 0 to +10Vdc proportional from 0 to rated output. Accuracy ±1%. Connectors: Input Line Connector: IEC 320 with EMI filter Output Line Connector: Depends upon polarity selected. See table and drawing. Other connectors and pinouts available on special order. Remote Monitor:USB and RS-232,RS-422 are standard. All digital monitors have an accuracy specification of 2%. Control Software: A Windows graphical user interface example is provided. built-in diagnostics can be performed over USB and RS232 RS-422. High Voltage Enable A hardware based,dry contact closure will enable the power supply into the high voltage on mode. Monitor Signals: Test points are made available at J2 for monitoring voltage and current outputs. The output polarity is positive from 0 to 10V equal to 0 to 100% of the output |